VFD control system

The drilling-rig VFD control system is a multi-drive variable-frequency speed-control system. VFD systems for rigs drilling from 3,000 to 12,000 meters are developed and produced, using fully digital vector-control voltage-type AC drives.

  • VFD

Last reviewed 2026-10-27 (Asia/Shanghai)

Row of dark variable-frequency drive cabinets with small red indicators.

System features

The drives are fully digital vector-control voltage-type AC variable-frequency devices, with V/F characteristic curves and field-oriented vector control. The PLC uses PRONET fieldbus communication for control, monitoring, and fault diagnosis.

  • High-performance speed control
  • Small starting current, high operating efficiency, and strong overload capacity
  • Feedback braking
  • Convenient and safe use, low noise, and easy maintenance

Technical parameters

Figures below are the configuration table printed for 30DB through 120DB. A cell with two lines in the catalog is written here with a slash.

Technical parameter30DB40DB50DB70DB80DB90DB120DB
Generator control cabinet3 sets3 sets3 sets4 sets4 sets5 sets5 sets
Frequency inverter600 kW × 1 and 800 kW × 1600 kW × 1 and 800 kW × 1800 kW × 2800 kW × 2 and 1100 kW × 21100 kW × 21100 kW × 41100 kW × 4
Dynamic braking1200 kW × 12400 kW × 13600 kW × 14800 kW × 1———
Comprehensive control cabinetS7-1500S7-1500S7-1500S7-1500S7-1500S7-1500S7-1500
Driller's consoleET200SPET200SPET200SPET200SPET200SPET200SPET200SP
Automatic drilling feed frequency cabinet45 kW × 155 kW × 175 kW × 190 kW × 190 kW × 2110 kW × 2110 kW × 2
Main transformer800 kVA × 11000 kVA × 11250 kVA × 11600 kVA × 12000 kVA × 12100 kVA × 12500 kVA × 1
MCC cabinet4 sets5 sets6 sets7 sets8 sets——
Soft starter system45 kW, 5 circuits, 1 set55 kW, 7 circuits, 1 set75 kW, 8 circuits, 1 set110 kW, 12 circuits, 1 set110 kW, 15 circuits, 1 set——

Questions buyers ask

What is the Hande drilling-rig VFD system?
It is a multi-drive variable-frequency speed-control system for rigs drilling from 3,000 to 12,000 meters, using fully digital vector-control voltage-type AC drives with V/F curves and field-oriented vector control.
How does the PLC communicate?
The catalog says the PLC uses PRONET fieldbus communication for control, monitoring, and fault diagnosis.
Which configurations are in the table?
The printed table columns are 30DB, 40DB, 50DB, 70DB, 80DB, 90DB, and 120DB, covering generator-control cabinets, frequency inverters, dynamic braking, transformers, MCC, and soft starters. Mud-pump and top-drive cabinets are on mud pump control and top drive control.

Cuéntenos el equipo.

Indique el país y el equipo.